Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T20CM06305
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/15/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Show gas pipe sizes in compliance with connected demand, G2413.3 & Table G2413.4(1). A 3/4" pipe is limited to 170,000 BTU for a 37' total developed length sysem. Update the size to 1". |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/02/2020 | VLEON1 | APPROVAL SHELF | Completed |
| 10/02/2020 | VLEON1 | OUT TO CUSTOMER | Completed |
| 10/02/2020 | VLEON1 | REJECT SHELF | Completed |