Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM06217
Parcel: 121062680

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM06217
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/23/2020 ANDREW CONNOR NPPO REVIEW Passed
09/25/2020 SSHIELD1 ENGINEERING REVIEW Passed
09/25/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM06217
1611 N Sahuara Av
Detached Ramada & Attached Patio
Residential (1st Review)

TRANSMITTAL DATE: September 25, 2020

This site is located in the R-1 zone (UDC 4.7.8).

1. The plot plan shall show the entire property.

2. Provide a perimeter yard setback from the attached pergola to the south property line.

3. The site plan shows an "EXISTING SHED" near the northwest corner of the house, this shed does not show on the most recent aerial photos and as it does not meet perimeter yard setbacks it will require a neighbor signoff to reduce the setback. Provide following information on the plot plan and have the owner of the property sign and date:
"My Name is and I am the owner of the property located at . I have reviewed the site plan and I have no objection to structure being located or constructed from the property line as depicted on the site plan.


Residential plot plan requirements can be found at:
https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
10/07/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM06217
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

STRUCTURAL PLANS:

1. Provide a complete roof framing plan with appropriate load carrying capacity. Show roof structural members with rafter ties (or ceiling joists) and collar ties (ridge straps) when the roof pitch is equal or greater than 3” to 12”, R802.3.

PLUMBING PLANS:

1. Gray water systems may only receive waste discharge from bathtubs, showers, lavatories, clothes washers and laundry trays, P3009.7. Remove the gray drain lines from the outdoor food preparation sink. Show the drainage fixture with connection to the public sewer system through the dwelling system, P2602.1.
2. Show gas pipe sizes in compliance with connected demand, G2413.3 & Table G2413.4(1). Provide a gas line isometric or table for showing the BTU demand and length of line to each gas appliance.

ELECTRICAL PLANS:

1. Notate the fountain receptacle with a location between 6 feet and 20 feet from the water edge, E4203.

If you have any questions, please contact:
Ken Van Karsen
(520) 791-5550
City of Tucson Residential Plan Review