Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T20CM06001
Parcel: 11107048B

Address:
3305 E WATER ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM06001
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/10/2021 SBLOOD1 ENGINEERING REVIEW Passed
08/18/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T20CM06001
3305 E Water Street
Permit un-permitted sheds, cockatiel & dove aviary, and chicken & duck coup
Residential (3rd Review)

TRANSMITTAL DATE: August 18, 2021

This site is located in the R-2 zone (UDC 4.7.9).

1. This comment was not fully addressed, provide street setback dimensions from the existing house to the street property lines and from the animal enclosures to the street property lines. Provide setback dimensions for all structures on site to the applicable property lines. Once provided the front and side street can be verified. If the existing house does not meet a minimum street perimeter yard of 20’-0” to the street property line along Water Street, Edith Blvd will be considered the front street and all the accessory structure will be considered to be located within the front yard and is not allowed per UDC Article 6.6.3.B.

2. This comment was not addressed correctly. The south and west street property lines are 15’ from the face of curb, not 15’6” as shown on the plan. Provide a dimension from the center line of Water St and Edith Bl to the face of curb and a dimension from the face of curb to the street property line. The dimension for both streets from center line to the face of curb is 15’ and from face of curb to property is 15’.

3. Per Tucson Code Section 4-57 Proximity of coop or place kept to dwellings. Except as otherwise provided, it shall be unlawful for any person to keep or maintain, within fifty (50) feet of the dwelling house of any other person within the city, any coop, house, shed or other structure, or yard, corral or enclosure for housing, keeping or caring for any pigeons or fowl of any kind. Demonstrate on the plan that the cockatiel avery is not within the 50’ setback to the homes to the north and east.

4. Clearly show the perimeter fence on the plan.

5. Per UDC Article 6.6.5.E.3 then maximum number of animal units is 24 for this parcel, each chicken counts as one (1) animal unit and each duck counts as two (2) animal units. Provide a note on the plan stating how many chickens and ducks you are proposing and the total number of animal units. No male fowl are allowed on site.

Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
08/31/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Passed