Permit Number: T20CM06001
Parcel: 11107048B

Address:
3305 E WATER ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM06001
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/08/2020 ANDREW CONNOR NPPO REVIEW Passed
09/08/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Passed
09/09/2020 JOHN VAN WINKLE ENGINEERING REVIEW Passed
09/17/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM06001
3305 E Water Street
Permit un-permitted sheds, cockatiel & dove aviary, and chicken & duck coup
Residential (1st Review)

TRANSMITTAL DATE: September 17, 2020

The room addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the R-2 zone (UDC 4.7.9).

1. Provide setback dimensions for all structures on site to the applicable property lines. Once provided the front and side street can be verified.

2. Per Unified Development Code (UDC) TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-1 zone the minimum perimeter yard setback for the north property line is 6' or 2/3 the height of the exterior wall, greater of the two. That said the four (4) sheds shown along the north property are required to meet the 6' setback or a neighbor sign off is required. If you elect to use the neighbor signoff provide the following on the plot plan and have your neighbor sign and date:

"My Name is __________________and I am the owner of the property located at . I have reviewed the site plan and I have no objection to structure being located or constructed 3'-0" from the property line as depicted on the site plan.

3. Provide a dimension from the center line of Water St and Edith Bl to the face of curb and a dimension from the face of curb to the street property line. The dimension for both streets from center line to the face of curb is 15' and from face of curb to property is 15'.

4. Show the entire property on the plan with dimensions for all property lines.

5. Provide the zoning for the adjacent properties on the plan.

Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956