Permit Number: T20CM05983
Parcel: 122091190

Address:
1715 N LOUIS LN

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM05983
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/18/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM05983
1715 N Louis Ln
Remodel and RV cover addition
Residential (1st Review)

TRANSMITTAL DATE: September 18, 2020

This site is located in the R-2 zone (UDC 4.7.8). .

1. Per UDC Article 6.6.3.C Accessory structures shall not exceed 12 feet in height, unless attached to a principal structure. A Board of Adjustment for Variance will be required for he 12'-4" RV structure, Board of Adjustment application available at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf

2. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). That said based on a 12' wall the required setback from the RV structure to the south and west property line is 8'-0", proposed setback is 1'-0". The reduced perimeter yard setbacks can be dealt with during the Board of Adjustment process or per UDC Article 6.6.2.D a neighbor setback waiver can be used. To use the setback waive provide the following information on the plan for all applicable owners and have them sign and date:
"My Name is and I am the owner of the property located at . I have reviewed the site plan and I have no objection to structure being located or constructed from the property line as depicted on the site plan.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
09/18/2020 SSHIELD1 ENGINEERING REVIEW Passed
09/18/2020 ANDREW CONNOR NPPO REVIEW Passed
10/01/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM05983
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL COMMENTS:

1. Provide plans for the patio upgrade as listed on the application.

SITE PLAN:

1. Identify the location of the patio upgrade.

STRUCTURAL PLANS:

1. Provide an engineer’s calculation, design and seal for the metal RV Cover assembly, R106.1.1.
2. Roof projections may not extend to a point closer than 2 feet from the property line. Provide notation for compliance with R302.1 (City of Tucson Amended) by removing the roof overhang near the property line, or provide a complete wall barrier with not less than one-hour fire-resistive construction.
3. If not providing the one-hour barrier and only 2 feet of the RV cover is removed near the property line then remaining roof projections extending into the 3-foot fire separation distance require not less than one-hour fire-resistive construction on the underside.

MECHANICAL PLANS:

1. Provide demand calculations in accordance with Manual J standards for new or replaced cooling systems, M1401.3, M1601.1.

If you have any questions, please contact:
Ken Van Karsen
(520) 791-5550
City of Tucson Residential Plan Review