Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T20CM05958
Parcel: 128100540

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T20CM05958
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/10/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Appliances (e.g. beverage dispensers, ice makers, etc.) to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps conforming to Section 608.14.1, IPC 2018 require backflow prevention. Specify the type of backflow prevention device required for each water connection. At a minimum, coffee machines and non-carbonated beverage dispensers require the use of a backflow preventer listed to either ASSE 1022, ASSE 1024, or an air gap. Reference: Sections 608.1, 608.3, and 608.17.1.2 IPC 2018.
09/10/2020 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
09/10/2020 ROBERT SHERRY WATER REVIEW Completed
09/21/2020 DTRAMME1 ENGINEERING REVIEW Passed
09/23/2020 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the following electrical plan review comments. Also provide a written response.
1. Provide receptacles spaced apart in the meeting/conference rooms as required per NEC art 210.71.
Ref; 2018 IBC sec, 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements.
09/28/2020 JPEELDA1 FIRE REVIEW Approved
10/06/2020 MALLORY RESS ZONING REVIEW Approved
10/06/2020 MRESS1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed
10/08/2020 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved