Permit Number: T20CM05923
Parcel: 134230820

Address:
6541 E COOPER ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM05923
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/01/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide a complete plan set for review. Include a Roof Framing Plan with dimensions, post locations, beam and rafter sizes; and a Section Detail noting footer size, rebar and all fastening points for posts and walls with structural components identified for 2018 IRC compliance.
Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits
12/21/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM05923
6541 E Cooper St
Carport Addition
Residential (2nd Review)

TRANSMITTAL DATE: December 21, 2020

The remodel and addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.1 - .9, & .11.

1. The proposed “2X OPEN LOATTICE TO CONNECT @ FASCIA, EA. BUILDING” does not meet the requirements of a 5’-0” wide solid connection from the proposed carport to the existing home that can support a 20 lb live load. Per UDC Article 6.6.3.B Detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line The connection proposed does not qualify as an attached structure and at a minimum must have at least a 5’-0” wide solid connection from the proposed carport to the existing home that can support a 20 lb live load. If you wish to maintain the 2’ x 2’ open connection a Board of Adjustment for Variance is required.

2. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). Based on a wall height less than 10’-0” the required street perimeter yard setback is 20’-0’, proposed setback is 5’-10”. A Design Development Option (DDO) may be use to reduce this setback. DDO requirements can be found at; https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. This DDO must be approved prior to approval of the building plans.

Plot plan requirements can be found at; https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956