Permit Number: T20CM05845
Parcel: 11917013H

Address:
3502 S 6TH AV

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T20CM05845
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2020 STEVE SHIELDS ZONING REVIEW Approved
09/14/2020 SSHIELD1 ENGINEERING REVIEW Passed
09/17/2020 JPEELDA1 FIRE REVIEW Approved
09/30/2020 PIMA COUNTY ELECTRICAL-COMMERCIAL REVIEW Approved
09/30/2020 PIMA COUNTY MECHANICAL-COMMERCIAL REVIEW Approved
09/30/2020 PC_CANDERS1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
09/30/2020 PIMA COUNTY WATER REVIEW Approved
12/03/2020 PIMA COUNTY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. On the mechanical plan, sheet M1.0, the exhaust location notes for manicure tables and pedicure chairs are reversed. Please correct. Ref. 2018 IMC 502.20.
12/03/2020 PIMA COUNTY BUILDING-COMMERCIAL REVIEW Reqs Change 2. Occupant loads for exiting purposes are determined using the occupant load factors in 2018 Table 1004.2 based on functions of each space multiplied by the floor area of each space. The occupant load for exiting is not determined by using the Occupancy and Use for the entire tenant area as determined by Chapter 3. Therefore, for the waiting room 188 SF/15 SF per occupant = 13 occupants, and for the business area 564 SF/150 SF per occupant = 4 occupants, for a total occupant load of 17. Please revise the Project Code Check on sheet TS.1.
3. This will not affect the plumbing fixture calculation as the ICC 2018 International Building Code Illustrated Handbook allow the Chapter 3 Occupancy classification for the entire space to be used for calculating required plumbing fixtures. Since this is B occupancy, 752 SF inside perimeter walls/150 SF per occupant = 5 occupants. A single restroom with 1 lavatory and 1 water closet is sufficient.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/26/2020 VFLORES1 APPROVAL SHELF Completed
10/26/2020 VFLORES1 OUT TO CUSTOMER Completed
10/26/2020 VFLORES1 REJECT SHELF Completed