Permit Number: T20CM05798
Parcel: 119223070

Address:
1863 W SAXONY RD

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM05798
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/19/2022 STEVE SHIELDS ZONING REVIEW Reqs Change FROM: PDSD Zoning Review

PROJECT: T20CM05798; Enclose Garage
Building Plans (4th Review)
1863 W Saxony Rd -R-1 Zone

TRANSMITTAL DATE: September 19, 2022

COMMENT: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).
This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.
The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).
1. Based on a wall height of 12’-0” the required perimeter yard setback from the garage to the west property line is 8’-0”, proposed setback is 2’-0”.
A Design Development Option (DDO) must be submitted and approved to reduce the required setback,
DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.
If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
09/19/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change 1. Comply with Zoning comments.

2. Show the door from a garage to dwelling with a 20-minute fire rating (or 1-3/8" solid core) with self-closing and self-latching provision, R302.5.1.