Permit Number: T20CM05732
Parcel: 126150810

Address:
4450 E COOPER CI

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM05732
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/28/2020 ELISA HAMBLIN ZONING REVIEW Reqs Change FROM: Elisa Hamblin, AICP
PDSD Zoning Review

PROJECT: T20CM05732; Carport
Building Plans (2nd Review)
4450 E COOPER CI – R-1 Zone

TRANSMITTAL DATE: December 28, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review comments were addressed.
1. Zoning has reviewed the building plans but cannot approve them at this time. It’s clear you wish to proceed with a Design Development Option (DDO) for reduced setbacks. In order for the DDO to proceed, the carport must be attached to the house. This was overlooked on the previous review. A minimum 5 ft of the carport must be directly attached to the house with a solid structure that can hold a 20 lbs. live load. Once corrected, the DDO can proceed. The required setback from the street is 20 ft or 1.5 times the wall height, whichever is greater, as measured from the property line. The proposed carport is illustrated with a 1 ft setback.
2. Per previous comment, the submitted site plan illustrates a greenhouse and other buildings on site which do not meet the required minimum 6 ft setback from property line. A neighbor sign-off can be sued to waive the required setback. Please paste the following text on the next submitted site plan with appropriate neighbors signature: “My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________”. It is noted that two waivers were provided on the site plan. Correction is needed to show all buildings on site, and accurate dimensions from the structures to the property lines. It appears there are 3 structures on the back of the property. Include dimensions and waivers for any structure that does not meet the minimum standard.

If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: building plans