Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM05622
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/31/2020 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 09/01/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 09/02/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T20CM05622 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Consolidate pages of construction plans into a single .PDF file as prescribed at the PDSD web site. https://www.tucsonaz.gov/pdsd/online-permits STRUCTURAL PLANS: 1. Identify the composition of the interior wall, R301.1. 2. Specify if the door opening requires engineered alteration (header) for maintaining structural integrity, R301.3. PLUMBING PLANS: 1. A second clothes washer standpipe may discharge to an exterior wall discharge point for immediate gray water usage. See the detail at https://www.tucsonaz.gov/files/pdsd/codes-ordinances/Grey_Water_Options_FINAL_.pdf The diverter valve system as shown does not meet the minimum requirement for usage without additional features. ELECTRICAL PLANS: 1. Clarify the electrical riser diagram, E3403. Show if the service drop is overhead or underground. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 09/14/2020 | PC_TGUTHEI1 | ZONING | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/14/2020 | PC_TGUTHEI1 | REJECT SHELF | Passed |
| 09/14/2020 | PC_TGUTHEI1 | APPROVAL SHELF | Passed |
| 09/14/2020 | PC_TGUTHEI1 | OUT TO CUSTOMER | Completed |