Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM05410
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/24/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: Steve Shields Site Section Manager PROJECT: T20CN05410 700 N Lazy J Way Attached Garage TRANSMITTAL: August 24, 2020 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-3). See Use-Specific Standards 4.9.7.B.6, .8, & .9. 1. The minimum setback is twenty feet (20) facing each interior property line (Table 6.3-1.A). Proposed perimeter yard setback from the proposed attached garage to the south property line is 10'-0" A DDO must be approved prior to approval of these building plans. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf |
| 08/24/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | T20CM05410 1) This project is subject to Hillside Development Zone requirements. Reference City of Tucson Unified Development Code section 5.2 and Technical Standards Manual section 9-01. It is possible that the original plans for the house show the maximum area that can be graded and that the proposed addition falls within the area already approved. If a copy of those plans is available, please included in response to these comments. 2) A separate grading plan is required according to Technical Standards Manual section 9-01 John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 08/24/2020 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 08/24/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Update the code reference on sheet #2 to 2018 IRC. Show the existing wall type between the porposed room and existing dwelling. Half hour rating is required such as 1/2" sheet rock. Remove the arc-fault notation; all garage receptacles are GFCI protected and arc-fault is not required outside of the dwelling. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/31/2020 | JGARCIA1 | APPROVAL SHELF | Completed |
| 08/31/2020 | JGARCIA1 | OUT TO CUSTOMER | Completed |
| 08/31/2020 | JGARCIA1 | REJECT SHELF | Completed |