Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM05184
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/10/2020 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 08/10/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 08/11/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | The simplified prescribed energy values for glazing is U=0.40, skylights U=0.65, ceiling R=38 and framed walls R=13. Mass wall requirement is R=4 when insulation is applied to ungrouted cells or exterior and R=6 when applied on the interior, N1102.1. Show a means of achieving the prescriptive values for the walls on the plans. |
| 08/24/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: Steve Shields Site Section Manager PROJECT: T20CM05184 7500 E Mary Dr. Master Bedroom Closet Addition TRANSMITTAL: August 24, 2020 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b). Proposed side street perimeter yard setback is 8'-8". Requirements for the Design Development Option (DDO) can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/24/2020 | VLEON1 | APPROVAL SHELF | Completed |
| 08/24/2020 | VLEON1 | OUT TO CUSTOMER | Completed |
| 08/24/2020 | VLEON1 | REJECT SHELF | Completed |