Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 1ST
Permit Number - T20CM05183
Review Name: REVISION - - 1ST
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/20/2021 | AWARNER1 | LANDSCAPE | REVIEW | Passed | |
| 08/26/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | |
| 08/27/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T20CM05138 323 N Warren Ave. – R-2 Remodel/Addition to Main House and New Sleeping Quarters (1st Revision) TRANSMITTAL: August 27, 2021 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the wall, see Unified Development Code (UDC) Article 6.4.5.b & Figure 6.4.5-A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). 1. For the main residence addition based on a proposed wall height of 12’-0” the required perimeter yard setback to the north property line is 8’-0” proposed perimeter yard setback is 6’-6” 2. For the sleeping quarters based on a proposed wall height of 12’-0” the required perimeter yard setback to the south property line is 8’-0” proposed perimeter yard setback is 6’-0” DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 08/27/2021 | SSHIELD1 | ENGINEERING | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/27/2021 | VVERA1 | OUT TO CUSTOMER | Completed |