Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM05086
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/07/2020 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 08/07/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | 1. PROVIDE THE STRUCTURE HEIGHT. Provide an engineer’s calculation, design and seal for framing over 12’ high, Table R602.10.5. 2. PROVIDE A MEANS OF LATERIAL SUPPORT. FASTEN TO THE DWELLING OR DIAGONAL BRACING, R106.1. 3. KEYED NOTE #8 CALLS FOR WELDING. 76. Field welded connections require special inspections. Identify the certified inspector on a special inspection request form to be included with the final submitted plans, UAC306.1.5. 4. UPDATE 7'-6" WIDTH AT FOOTING/COLUMN DETAIL. |
| 08/10/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 08/17/2020 | MALLORY RESS | ZONING | REVIEW | Reqs Change | FROM: Mallory Ress PDSD Zoning Review Section PROJECT: T20CM05086 CARPORT ADDITION (1st Review) 8433 E PENA BLANCA DR TRANSMITTAL DATE: 8/17/20 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: Show height of structure on elevations. 02. COMMENT: Design Development Options (DDO) comments are forthcoming. The height of the structure must be known to provide DDO comments for reduced setbacks to the west and south property lines. The required setback to the south (street) lot line is 20’ or 1 ½ times the height of the wall facing the street measured from the street property line. It is likely that the required setback to the street perimeter lot line will be 20’ however, the height of the structure is needed to confirm. The required setback to the west lot line is 6’ or 2/3 the height of the wall facing the west lot line. The height of the structure is needed to confirm whether a reduced setback is requested to the west lot line. 03. COMMENT: The rear patio addition appears to have been constructed after Spring 2006 and before Spring 2008 without proper approvals. Provide approvals or provide the height of the rear patio addition so that required setbacks may be calculated. If the structure has not received approvals, this permit may be amended to include the rear patio addition. If you have any questions about this transmittal, Contact Mallory Ress by email Mallory.Ress@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |