Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM05085
Parcel: 121093100

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM05085
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/07/2020 ANDREW CONNOR NPPO REVIEW Passed
08/07/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM05085
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.


SITE PLAN:

1. Indicate the location of buildings, utility meters and gas, water, electric and sewer lines from property line to building, R106.1.1.

FOUNDATION PLANS:

1. Dimension the footing length, width, and depth into undisturbed soil for each footing type and condition, R403.1.1.
2. Provide concrete foundations for anchoring interior braced wall line sills with ½” anchor bolts with 7” embedment, R403.1.6.

FLOOR PLANS:

1. Show the location of support walls or posts, R106.1.1. Each support structure requires a foundation, either existing or proposed.

SECTIONS - DETAILS:

1. Provide a Shed wall detail showing a 6” minimum separation of exterior siding or sheathing above finished grade, R317.1 item 5. Or 2” above paved areas, R703.7.2.1. This may require a design with concrete stems.
2. Show the method of roof fastening to the dwelling.
3. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended.

ELECTRICAL PLANS:

1. Show any extended items such as lighting.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
08/10/2020 SAMUEL ROGERS ZONING REVIEW Reqs Change FROM: Samuel Rogers - Planner
PDSD Zoning Review Section

PROJECT: T20CM05085 (Project Number)
Shed Addition (1st Review)
1880 N Frances Bl

TRANSMITTAL DATE: 08/10/2020

DUE DATE: 07/29/2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


01. COMMENT: A site plan is required; additional zoning comments may be provided upon the submittal of a site plan. For plot plan requirements see: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

You have an existing site plan under the solar permit T16CM06348, you can find the site plan by going to the City's Property Research Online Site (https://www.tucsonaz.gov/PRO/pdsd/) and search for permit number T16CM06348. You can use this solar permit site plan as a base, but see the plot plan requirements for additional information that will need to be added.




If you have any questions about this transmittal, contact Samuel Rogers at (520) 837-6932 or at Samuel. Rogers@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans
08/10/2020 SROGERS2 ENGINEERING REVIEW Passed