Permit Number: T20CM04989
Parcel: 11942006L

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM04989
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/04/2020 ANDREW CONNOR NPPO REVIEW Passed
08/04/2020 LOREN MAKUS ENGINEERING REVIEW Passed
08/04/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM04989
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Provide plans showing compliance with AE102.2 additions and alterations certified under the National Manufactured Housing Construction and Safety Standards Act of 1974, or provide a design by a registered Arizona engineer with sealed plans, R401

STRUCTURAL PLANS:

1. Manufactured buildings are not designed for accepting additional structural loads, R301.1.3. Provide an engineer’s calculation, design and seal for determining appropriate fastening methods. Or, provide plans witthout structural connection to the manufactured dwelling.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
08/06/2020 ELISA HAMBLIN ZONING REVIEW Reqs Change T20CM04989
8/6/20
Provide dimensions on plot plan which indicate distances between structures. Porch must be minimum of 6 ft from adjacent manufactured home (on next lot). Correct dimension and resubmit.
Elisa Hamblin, AICP
Principal Planner
elisa.hamblin@tucsonaz.gov