Review Date Reviewer's Name Type of Review Description Status Comments
05/06/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change PLAN REVIEW COMMENTS
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide a PDF file of plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code. All features of the plans are to show compliance with the 2018 IRC before permit approval.

GENERAL REQUIREMENTS:

Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits

FOUNDATION PLAN:
1. Dimension the footing length, width, and depth into undisturbed soil for each footing type and condition, R403.1.1.

FRAMING PLAN:
1. Provide a complete roof framing plan with beams and rafters sized with appropriate load carrying capacity, R301.1.

SECTIONS - DETAILS:
1. Show the Post Section Detail with #4 rebar in the footing, R403.1.
2. Notate and specify the size and length of anchor bolts, R403.1.
3. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended.
4. Show connection at dwelling with fasteners (rafter on top plate with H2.5 or ledger with rafter hangers).

Please contact the plans reviewer if you have any questions:
Ken Van Karsen, 520 837-4912
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
05/24/2021 STEVE SHIELDS ZONING REVIEW Reqs Change FROM: PDSD Zoning Review

PROJECT: T20CM04892
Carport addition and Fence (lot split under S20-034)– (4th Review)
5808 E Beverly

TRANSMITTAL DATE: May 24, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. This comment was not addressed. COMMENT: Provide a complete site plan, with lot coverage calculation. The survey document provided is a good start. Ensure that lot coverage calculations are provided on the same document. Include existing vehicle use area, carport, existing dwelling and any existing accessory structures as part of lot coverage calculation

2. This comment was not addressed. COMMENT: Provide elevations, showing the height of the carport addition from all sides. Plot Plan (example document) and page two of Plot Plan that were provided on resubmittal, show different heights for the carport. Be sure to provide the height of the carport posts from natural grade to under roof. If the height is 9 feet or less, a 6 foot setback is required from posts. A two foot overhang into this required setback is allowed.
3. As no readable elevations were provided setback requirements cannot be verified. But based on the partial plot plan provided it appears that the carport does not meet perimeter yard setback to the east property. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). A Design Development Option (DDO) will need to be submitted and approved prior to approval of this plan. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.
4. Several of the provided drawings are not readable.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and elevations.