Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T20CM04892
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/21/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Consolidate pages of construction plans into a single .PDF file as prescribed at the PDSD web site. https://www.tucsonaz.gov/pdsd/online-permits Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits SITE PLAN: 1. Indicate the location of buildings and any utilities supporting the proposed structure. FOUNDATION PLAN: 1. Dimension the footing length, width, and depth into undisturbed soil for each footing type and condition, R403.1.1. FRAMING PLAN: 1. Provide a complete roof framing plan with beams and rafters sized with appropriate load carrying capacity, R301.1. SECTIONS - DETAILS: 1. Show the Post Section Detail with #4 rebar in the footing, R403.1. 2. Notate and specify the size and length of anchor bolts, R403.1. 3. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. 4. Show connection at dwelling with fasteners (rafter on top plate with H2.5 or ledger with rafter hangers). Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
| 05/04/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: PDSD Zoning Review PROJECT: T20CM04892 Carport addition and Fence (lot split under S20-034)– (3rd Review) 5808 E Beverly TRANSMITTAL DATE: May 4, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. This comment was not addressed. COMMENT: Provide a complete site plan, with lot coverage calculation. The survey document provided is a good start. Ensure that lot coverage calculations are provided on the same document. Include existing vehicle use area, carport, existing dwelling and any existing accessory structures as part of lot coverage calculation 02. This comment was not addressed. COMMENT: Provide elevations, showing the height of the carport addition from all sides. Plot Plan (example document) and page two of Plot Plan that were provided on resubmittal, show different heights for the carport. Be sure to provide the height of the carport posts from natural grade to under roof. If the height is 9 feet or less, a 6 foot setback is required from posts. A two foot overhang into this required setback is allowed. Several of the provided drawings are not readable. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and elevations. |