Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - W/ COMM BLDG/ZONING/ENGINE
Permit Number - T20CM04892
Review Name: RESIDENTIAL - W/ COMM BLDG/ZONING/ENGINE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/31/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 08/05/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 08/06/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Provide a complete plan set for review. Include a completed Site Plan showing a minimum of 3’ separation from property line; Roof Framing Plan with dimensions, post locations, beam and rafter sizes; and a Section Detail noting footer size, rebar and all fastening points with structural components identified for 2018 IRC compliance. K E Van Karsen 520 837-4912 |
| 08/06/2020 | ELISA HAMBLIN | ZONING | REVIEW | Reqs Change | T20CM04892 8/6/20 Provide a residential plot plan which meets the requirements found online here: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf Provide elevation/height drawings of the proposed carport to determine applicable setbacks. If a fence is proposed, provide details as to location and height. Zoning permits a maximum 6 ft solid wall/fence on the propoery line. Taller heights require visual permeability or setbacks are met. Elisa Hamblin, AICP Principal Planner elisa.hamblin@tucsonaz.gov |
| 08/06/2020 | EHAMBLI1 | BUILDING-COMMERCIAL | REVIEW | Passed |