Permit Number: T20CM04834
Parcel: 117072560

Address:
710 S 2ND AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM04834
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/28/2020 ANDREW CONNOR NPPO REVIEW Passed
07/30/2020 LOREN MAKUS ENGINEERING REVIEW Passed
07/31/2020 MALLORY RESS ZONING REVIEW Needs Review ZONING REVIEW TRANSMITTAL

FROM: Mallory Ress
Planner

PROJECT:
T20CM04834
710 S 2ND AV
MASTER SUITE ADDITION/REMODEL

TRANSMITTAL: 7/31/20
COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the HR-3 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

The applicant is proposing a 10’wall height to the north property line. A 6’8” setback is required. A 6’ setback is proposed.

Existing shed at southwest corner of property has not received approvals. Setback to the west property line is 1’5”. Setback to south property line is 1’2”. A 6’ setback is required to the south and west property lines.

Historic Review required.
08/05/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change PROVIDE A COMPLETE PLAN SET FOR REVIEW