Permit Number: T20CM04806
Parcel: 11941015F

Address:
1921 W AJO WY

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM04806
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/25/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide a complete plan set (no cut-off edges) for review. Include a completed Site Plan; Roof Framing Plan with dimensions, post locations, beam and rafter sizes; and a Section Detail noting pad footer size, two #4 rebar each-way and all fastening points ledger and H2.5 structural components identified for 2018 IRC compliance.

K E Van Karsen
520 837-4912
09/01/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM04806
1921 W Ajo Way
Porch Addition
Residential (2nd Review)

TRANSMITTAL DATE: September 1, 2020

The room addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

1. The plot plan shall show the entire parcel and be drawn at an Engineering scale, i.e. 1" = 10'. The provided plan is not to scale.

2. Show all property lines with the distance and bearing.

3. Provide a lot coverage calculation on the plan that meets the requirements of Unified Development Code (UDC) Article 6.4.3.

4. Provide setback dimensions from the proposed porch.

5. The drawings shall be submitted as a single multi-page PDF File.

Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

Final Status

Task End Date Reviewer's Name Type of Review Description
09/04/2020 VLEON1 APPROVAL SHELF Completed
09/04/2020 VLEON1 OUT TO CUSTOMER Completed
09/04/2020 VLEON1 REJECT SHELF Completed