Review Date Reviewer's Name Type of Review Description Status Comments
07/23/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
07/24/2020 ANDREW CONNOR NPPO REVIEW Passed
07/24/2020 DTRAMME1 ENGINEERING REVIEW Passed
08/05/2020 MALLORY RESS ZONING REVIEW Reqs Change Model Plan T19-M0003 indicates a finish floor height of 9' and a height from natural grade for the north and south elevations of 10'7 1/2". This height requires a DDO application. Below are comments relative for an application for a DDO. In the alternative, if possible, applicant may submit site plan showing conformance with setback requirements. A 7'1" setback is required to the North and South property lines

FROM: Mallory Ress, Planner Mallory.Ress@Tucsonaz.gov


PROJECT:
T20CM04705
3410 S BELMAR AV
NEW SFR

TRANSMITTAL: 8/5/20
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

The applicant is proposing to construct a model home, T19-M0003, the model plans show a wall height from natural grade of 10’7 1/2" for the North and South elevations. A setback of 7’1" is required to the north and south property lines. A setback of 6’ is proposed to the north property line. A setback of 6’6" is proposed to the south property line.

DDO required.

https://www.tucsonaz.gov/files/pdsd/2019_DDO_for_Setback_and_Height_UDC.pdf