Permit Number: T20CM04694
Parcel: 140132620

Address:
2203 E BALSAM CI

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM04694
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/08/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM04694
2203 E Balsam Cir
Front porch and carport
Residential (2nd Review)

TRANSMITTAL DATE: September 8, 2020

The plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

1. This comment was not addressed and these dimensions need to be provided on the plot plan not a separate sheet. Provide a dimension from the centerline of the street to the face of curb and from the face of curb to the property line. The distance from centerline to face of curb is 15' and from face of curb to property line is 10'.

2. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). Based on a wall height of 11'-6" the required street perimeter yard setback is 20'-0", proposed street perimeter yard is 5'-0"/ That said a Design Development Option (DDO) must be applied for and approved prior to approval of these plans. DDO application can be found at; https://www.tucsonaz.gov/files/pdsd/2019_DDO_for_Setback_and_Height_UDC.pdf
Zoning does not recommend that you apply for the DDO until comments 3 & 4 have been addressed.

3. This comment was not fully addressed, provide a setback dimension from the midpoint of the proposed carport to the east property line. As the proposed carport does not run parallel to the property line the setback can be averaged. Provide a setback dimension from the southeast corner of the proposed carport to the east property line and from the midpoint of the proposed carport to the east property line. Based on the height shown on sheet 3 of the plans, 11'-6" the required perimeter yard setback at the midpoint of the carport is 7'-8.

4. This comment was not addressed. Provide a street perimeter yard setback from the proposed porch to the street property line. Once the dimension is provided additional comments maybe forth coming. A DDO may be required for this perimeter yard setback.

5. It appears that you are showing the back of sidewalk as your street property line, this is not correct and the sidewalk should be shown 1' south of the street property line.

6. The drawing set shall be submitted as a single multipage PDF file.

Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
09/17/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Consolidate pages of construction plans into a single .PDF file as prescribed at the PDSD web site. https://www.tucsonaz.gov/pdsd/online-permits

Final Status

Task End Date Reviewer's Name Type of Review Description
10/01/2020 PC_TGUTHEI1 OUT TO CUSTOMER Passed
10/01/2020 PC_TGUTHEI1 REJECT SHELF Passed
10/01/2020 PC_TGUTHEI1 APPROVAL SHELF Passed