Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM04694
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/24/2020 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 07/24/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 07/29/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: T20CM04694 2203 E Balsam Cir Front porch and carport Residential (1st Review) TRANSMITTAL DATE: July 29, 2020 The plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. 1. Provide a dimension from the centerline of the street to the face of curb and from the face of curb to the property line. The distance from centerline to face of curb is 15' and from face of curb to property line is 10'. 2. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). That said a Design Development Option (DDO) must be applied for and approved prior to approval of these plans. DDO application can be found at. https://www.tucsonaz.gov/files/pdsd/2019_DDO_for_Setback_and_Height_UDC.pdf Zoning does not recommend that you apply for the DDO until comments 3 & 4 have been addressed. 3. Provide a setback dimension from the southeast corner of the proposed carport to the east property line and from the midpoint of the proposed carport to the east property line. Based on the height shown on sheet 3 of the plans, 13'-6" the required perimeter yard setback at the southeast corner is 4'-6". Based on the height shown on sheet 3 of the plans, 13'-6" the required perimeter yard setback at the midpoint is required to be 9'-0". Once the dimensions are provided additional comments maybe forth coming. A DDO may be required for this perimeter yard setback. 4. Provide a street perimeter yard setback from the proposed porch to the street property line. Once the dimension is provided additional comments maybe forth coming. A DDO may be required for this perimeter yard setback. 5. The lot coverage calculation needs to be updated to include the vehicle use area between the proposed carport and the street property line. Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 08/03/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed |