Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM04651
Parcel: 110050920

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM04651
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/23/2020 ANDREW CONNOR NPPO REVIEW Passed
07/24/2020 LOREN MAKUS ENGINEERING REVIEW Passed
07/29/2020 STEVE SHIELDS ZONING REVIEW Approved
08/03/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change PROFILE VIEW: CHANGE CODE TO 2018 IRC
SHOW RAFTERS CONNECTED TO THE LEDGER WITH RAFTER HANGERS.
SHOW A PAD FOOTER BELOW EACH POST 12" INTO THE EARTH WITH TWO #4 REBAR EACH WAY.
FRONT VIEW: SHOW A PAD FOOTER BELOW EACH POST 12" INTO THE EARTH WITH TWO #4 REBAR EACH WAY. THIS DEPTH IS IN ADDITION TO THE SLAB THICKNESS WHICH IS ON THE EARTH SURFACE.