Permit Number: T20CM04596
Parcel: 120072360

Address:
332 W LINCOLN ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM04596
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/12/2021 NICHOLAS ROSS ZONING REVIEW Reqs Change Per UDC Table 6.3-2.A the perimeter yard setback for the carport to the east property line is six (6) feet, or two-thirds (2/3) the height of the structure's wall facing the east property line. For a carport/porch structure the wall height is measured from design grade to where the beams meet the roof joists. Since no heights were provide on the plan additional comments will be forth coming once all required information is provided. As it appears that the perimeter yard setback to the east property line is less than 1'-0" a Board of Adjustment for Variance will be required to reduce the perimeter yard setback.
01/20/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change PROVIDE PLANS SHOWING APPROPRIATE FIRE RATED CONSTRUCTION FOR ALL STRUCTURES LOCATED WITHIN THE 3 FOOT FIRE SEPARATION DISTANCE TO PROERTY LINES.