Permit Number: T20CM04596
Parcel: 120072360

Address:
332 W LINCOLN ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM04596
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/25/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM04596
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

SITE PLAN:

1. Indicate the setback to property line and square footage of existing and proposed structures, R106.1.1.

FLOOR PLANS:

1. Show porch roof structures with one-hour fire-resistive wall construction separating the structure from the property line in compliance with IBC Table 721.1(2), or show a clear 3’ fire separation distance.
2. Roof projections may not extend to a point closer than 2 feet from the property line. Provide notation for compliance with R302.1 (City of Tucson Amended) by removing the roof overhang near the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction.

STRUCTURAL PLANS:

1. Show rafter and beam sizes with appropriate load carrying capacity, Table R802.4.1 and R301.1.

SECTIONS - DETAILS:

1. Update the footer detail showing #4 rebar reinforcement, two each-way with 3” clearance from earth, R403.1.3.5.3.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
09/01/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM04596
332 W Lincoln St
Porch and Carport additions
Residential (2nd Review)

TRANSMITTAL DATE: September 1, 2020

The plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. As you are proposing a change in the scope of work provide a revised and signed application to only show "ROOF MOUNTED PHOTOVOLTAIC SYSTEM"

If you have any questions about this transmittal, please contact me at
Steve.Shields@tucsonaz.gov or (520) 837-4956