Permit Number: T20CM04582
Parcel: 118038210

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM04582
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/02/2021 ALEXANDRA HINES ZONING REVIEW Approved Comment not addressed from previous submittal review. In resubmittal, provide comment response letter with plan set to respond how comments are addressed.

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 19’-4” the required perimeter yard setback is 12’-11”, proposed perimeter yard setback is not provided but it does not appear that the setback is met. Provide the proposed setback so that complete comments can be provided for the Design Development Option.

Alexandra Hines
alexandra.hines@tucsonaz.gov
02/02/2021 ALEXANDRA HINES ZONING REVIEW Approved Updated plan on 1/7/2021 shows setback compliance.