Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T20CM04556
Parcel: 115041610

Address:
1237 N EUCLID AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM04556
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/26/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM04556
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

Sample plans are available on request. PDSD-Residential@tucsonaz.gov

SECTIONS - DETAILS:

Provide structural details showing code compliant materials and fasteners. Show construction requirements: anchor bolt size, insulation placement and rating, ledger fasteners.

PLUMBING PLANS:

Provide piping details including yard water pipe size.

ELECTRICAL PLANS:

Provide wiring details showing code compliant devices and sizes. Show lighting control at each doorway (both sides) and arc-fault protection.

INTERNATIONAL ENERGY CONSERVATION CODE:

Provide insulation details showing code compliant materials and sizes, N1101. The simplified prescribed energy values for glazing is U=0.40, skylights U=0.65, ceiling R=38 and framed walls R=13. Mass wall requirement is R=4 when 50% of insulation is exterior and R=6 when applied interior, N1102.1. Block walls are typically furred for space containing wiring and insulation. The unvented ceiling usually has both foam board and batt insulation totaling R-38.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
09/08/2020 STEVE SHIELDS ZONING REVIEW Approved