Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM04474
Parcel: 14023182C

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM04474
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/01/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change 1. Provide a landing or floor surface at all exterior doors. A landing must be at least as wide as the door it serves and 36” in the direction of travel, R311.3.

2. Dwelling alterations require the installation of smoke alarms at existing bedrooms, R314.2.1. Provide notation if the smoke alarms are existing or proposed.

3. Show at least one wall switch controlled light at outdoor entrances or exits, E3903.3.
09/08/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T20CM04474
6225 S Morris Bl
Addition to Mobile Home
Residential (2nd Review)

TRANSMITTAL DATE: September 8, 2022

COMMENT: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the MH-1 zone (UDC 4.7.10). A Mobile Home (SFR) is a permitted use in this zone (Table 4.8-2).

1. This comment was not addressed correctly. Provide a plot plan that meets the follow requirements and shows the entire site. Review the Residential plot plan requirements and provide all required items on the plan. https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf.
a. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” = 20’ etc.
b. Indicate the name of the owner on the plot plan.
c. Provide a lot coverage calculation on the plot plan.
d. Show all structures that are on the entire parcel.
e. Show all utility lines on the plot plan.
f. Cleary show the proposed addition on the plot plan and provide all applicable perimeter yard setbacks on the plot plan.
g. Indication the zoning of this parcel and all adjacent parcels on the plot plan.
h. Provide the legal descriptions, “SOUTHLAND PARK LOT 21 BLK 9” on the plot plan.
i. Provide a density calculation on the plan.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.