Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T20CM04359
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/29/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PROVIDE AN ENGINEER STAMP ON THE PLANS FOR THE METAL DECK. A STRUCTURAL REPORT IS REQUIRED FOR A PERFORMANCE DESIGN WHEN MINIMUM SIZES ARE NOT CODE COMPLIANT WITH THE 2018 IRC, R301.1. |
| 10/29/2020 | ALEXANDRA HINES | ZONING | REVIEW | Reqs Change | COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). The maximum height of a wall or fence within a perimeter yard shall be six (6) feet (UDC Section 6.6.2.I). The maximum height of a retaining wall is ten (10) feet from design grade and no higher than six (6) feet measured from the top of the retaining portion of the wall (UDC Section 6.6.2.I.2). The proposed height of the East, South, and West CMU wall is seven (7) feet. 1. Apply for DDO approval at https://www.tucsonaz.gov/pdsd/planning-zoning. Or redesign wall to six (6) feet. Alexandra Hines Alexandra.hines@tucsonaz.gov |