Permit Review Detail
Review Status: Active
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM04353
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/10/2020 | PC_JEDER1 | NPPO | REVIEW | Passed | |
| 07/13/2020 | PIMA COUNTY | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T20CM04353 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Sample plans are available on request. PDSD-Residential@tucsonaz.gov SITE PLAN: Provide a site plan showing all buildings, R106.1.1. Show setbacks. FLOOR PLAN: Provide a floor plan showing each room with labeled function. Scale ¼” = 1’. Show window size. Include adjacent rooms for verifying egress. SECTIONS - DETAILS: Provide structural details showing code compliant materials and fasteners. Show complete foundation with dimensions, anchor bolts and rebar. MECHANICAL PLANS: Provide equipment details showing code compliant components and sizes. ELECTRICAL PLANS: Provide wiring details showing code compliant devices and sizes. Show circuit size with receptacles at all walls and lighting control at each doorway. INTERNATIONAL ENERGY CONSERVATION CODE: Provide insulation details showing code compliant materials and sizes, N1101. Show insulation rating. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 07/29/2020 | ALEXANDRA HINES | ZONING | REVIEW | Reqs Change | 1. Provide site plot plan. Include information on site plan like lot coverage calculation and height (see example at https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf). 2. You can use existing plot plan on tucsonaz.gov/pro. Search by activity number, T12CM05422, and click Constrplans in the Documents table to view it. 3. Upload plan sheets as one PDF file. Alexandra Hines |
| 07/29/2020 | AHINES2 | ENGINEERING | REVIEW | Passed |