Permit Number: T20CM04335
Parcel: 13212047H

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM04335
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/10/2020 PC_JEDER1 NPPO REVIEW Passed
07/13/2020 PIMA COUNTY BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM04335
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

STRUCTURAL PLANS:

1. Provide a complete roof framing plan with rafters sized with appropriate load carrying capacity, R301.1. Show the beam size supporting the roof loading. Truss layout perpendicular to supporting beam.
2. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1. Show truss calculations with cross-reference to the plans, R802.10.2. Notate the size and weight of attic or roof mounted equipment on the Roof Framing Plan required for the truss design, M1401.

SECTIONS - DETAILS:

1. Roof shingles may be used on roof slopes of 2:12 or greater R905.2.2. Select a roof system that complies with R905.
2. Detail the fastening of the truss system to the dwelling, R301.1.

OUTDOOR LIGHTING CODE

1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
07/29/2020 ALEXANDRA HINES ZONING REVIEW Reqs Change 1. Provide additional information on site plan like lot coverage calculation and height (see example at https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf).
2. Provide completed Permit Application at https://www.tucsonaz.gov/files/pdsd/forms/PERMIT_APPLICATION_1-16-19_fillable.pdf.
3. Upload plan sheets as one PDF file.

Alexandra Hines
07/29/2020 AHINES2 ENGINEERING REVIEW Passed