Permit Number: T20CM04297
Parcel: 133102820

Address:
1661 N GOEBEL AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM04297
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/08/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM04297
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

STRUCTURAL PLANS:

1. Show a beam size with appropriate load carrying capacity, R301.1. Update the beam to 4x8 for the span greater than 10’.
2. Show the required joist/rafter bearing contact to supporting members, R502.6 & R802.6. The fascia board may not serve as a beam, ridge board or load bearing ledger. Extend the rafters to the load bearing wall with appropriate connection.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
07/24/2020 ANDREW CONNOR NPPO REVIEW Passed
07/31/2020 DTRAMME1 ENGINEERING REVIEW Passed
08/05/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM04297
1661 N Goebel Ave
Expand and Repair Rear Porch
Residential (1st Review)

TRANSMITTAL DATE: August 5, 2020

The plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the RX-1 & RX-2 zone (UDC 4.7.6). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-3). See Use-Specific Standards 4.9.7.B.6, .8, & .9.

1. The plans submitted do not the property lines. Provide a plan that clearly shows the property lines.

2. Based on the most current aerial photos on MapTucson there is a shed located southwest of the existing carports. There are no compliance permits in our system for this shed. This shed does not appear to meet the required perimeter yard setbacks of twenty feet (20) facing the south property line (Table 6.3-1.A). Show this shed on the plan and provide a neighbor setback waiver signoff as shown below. The following statement must be provided on the plot plan: "My Name is Eleanor O'Hara and I am the owner of the property located at 1631 N Goebel Ave. I have reviewed the plot plan and I have no objection to structure being located or constructed _____ from the property line as depicted on the site plan.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956