Permit Number: T20CM04180
Parcel: 103190070

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM04180
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/18/2020 ELISA HAMBLIN ZONING REVIEW Reqs Change FROM: Elisa Hamblin, AICP
PDSD Zoning Review

PROJECT: T20CM04180; Storage container and RV cover
Building Plans (2nd Review)
2880 N Silver Spur Dr – RX-2 Zone

TRANSMITTAL DATE: September 18, 2020
DUE DATE: September 17, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review comments were addressed.

1. Zoning has reviewed the building plans but cannot approve them at this time. Previous comment from Zoning on 7/31 still stands. Per UDC Article 6.6.3.C Accessory structures shall not exceed 12 feet in height, unless attached to a principal structure. Per UDC Article 6.4.4.A the height of a structure with a pitched room is measured from the midpoint of the pitched roof. Based on the drawings provided and the pitch shown the height of the RV structure measured to the midpoint is 12-1 ½". A Board of Adjustment for Variance is required prior to approval of the plans. Alternate option is to attach the accessory structure to the main house with a minimum 5 ft wide breezeway.

If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised building plans
09/23/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change STRUCTURAL CALCS AND BUILDING S1 & S2 PLANS ARE COMPLETED. AWAITING COMPLETED SITE PLAN FOR IDENTIFING TOTAL STRUCTURE SQUARE FOOTAGE ON PROPERTY.