Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM03925
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PROVIDE A SINGLE PDF FILE WITH A SITE PLAN, ROOF FRAMING PLAN AND SECTION DETAIL. PROVIDE A FOOTER DETAIL WITH TWO #4 REBAR EACH WAY AT 3" ABOVE THE BOTTOM. SHOW ANY ROOF SHEATHING SUCH AS 1/2" OSB WITH COVERING. PROVIDE BEAM SIZES APPROPRIATE FOR THE LIVE AND DEAD ROOF LOADING. PROVIDE DIAGONAL BRACING FOR LATERIAL STABILITY. |
| 07/13/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Passed | |
| 07/15/2020 | MALLORY RESS | ZONING | REVIEW | Reqs Change | The submitted materials have been reviewed and the following comments must be addressed for zoning: 1. No permit was received for the addition of the shed in the northwest corner of the property. Shed is under 200 sq ft and does not require inspections. However, zoning compliance is required. Height of shed and setbacks to North and West property line must be shown. Height cannot exceed 12ft and shed must be setback 6ft or 2/3 the height of the structure wall from the applicable property line, whichever is greater. 2. Site coverage calculation for existing and proposed structures must be shown on the site plan. Applicant should take the total lot size and show total coverage as a percentage for existing structures, vehicle use area and proposed structures. Total shall not exceed 70% lot coverage. 3.Show setback of ramada to the north property line. 4. It appears that the ramada is proposed such that the peak of the roof faces the west (alley) property line, if this is the case the wall height used to determine the setback appears to be 10 ft. 10 feet height requires a 6'8" setback. Setback to west property line is not met. 5. Height of masonry wall must be shown. Next steps: Submit revised site plan and construction drawings as a single PDF. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/04/2020 | VLEON1 | APPROVAL SHELF | Completed |
| 08/04/2020 | VLEON1 | OUT TO CUSTOMER | Completed |
| 08/04/2020 | VLEON1 | REJECT SHELF | Completed |