Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T20CM03593
Parcel: 12406132A

Address:
1050 E 8TH ST

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T20CM03593
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/11/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change PREVIOUS REVIEW COMMENTS:
1. Sheet AS-100: Please indicate all relevant codes on this sheet along with new material strengths (wood, masonry, concrete, reinforcing, steel, etc.).
2. Sheet A-102: Please provide a Code Analysis on this sheet for the Leasing Center (some is already included in the General Notes). Include the Occupancy Classification, Construction Type, Square Footage, Occupant Load, Sprinklers/No Sprinklers, and Exit Requirements (number of exits and exit width). Indicate there is no new work on the second floor.
3. Sheet A-102; General Notes (Note 3): This note indicates MEP trades will be design build. All design and drawings for these reviewers will be required on the permit drawings.
4. Sheet A-102; Keynotes: Please indicate in a note that not all Keynotes are includedon the plans and elevations on this sheet.
5. Sheet A-102; Keynotes (27): The size of the new steel lintel must be indicated in this note. In addition, provide a detail indicating the lintel and how it is to be inserted and supported in place.
6. Sheet A-102; First Floor Plan: Keynote 33 references a storefront door. Please revise the Keynote number (five locations).
7. Sheet A-102; First Floor Plan: Keynote 29 references a 20 minute rated door. Should Keynote 28 reference a rated wall assembly? If so, provide a U.L. Listing Number for that wall assembly.
8. Sheet A-102; First Floor Plan: Keynote 31 references a new CMU wall. Please indicate the wall reinforcing, and provide details at the top and the bottom of the new wall.
9. General: Please provide a valuation (labor + materials) for this project.
10. General: Please provide written responses to all review comments.
02/11/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Comment not addressed. [Initial comment: Demonstrate energy code compliance for the alterations to the building envelope using calculations based on the current code. Reference: Sections C103.2, C303, C503.1, and C503.3, International Energy Conservation Code 2018.]
2. Comment not addressed. [Initial comment: Provide construction documents drawn to scale and with sufficient detail and clarity to demonstrate that any proposed mechanical work complies with the applicable codes. Reference: Section 107.2.1, IBC 2018.]
02/22/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

PROJECT: Wildcat Leasing and Fitness Remodel
T20CM03594 (2nd Review)
1050 E 8th Ave

TRANSMITTAL DATE: February 22, 2021

1. Zoning has reviewed the building plans but until DP19-0261 has been approved Zoning cannot approve the building plans. Also unit all other PDSD Commercial Plans reviewers have approved the building plans Zoning cannot approve.

If you have any questions about this transmittal, please contact Elisa Hamblin, Elisa.Hamblin@tucsonaz.gov
02/22/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the following Electrical Plan Review comments. Provide a written response.

The previous Electrical comments were not addressed and the written response could not be located in the second plan submittal documents. See previous Electrical plan review comments.
03/01/2021 JPEELDA1 FIRE REVIEW Reqs Change Plans shall indicate codes being used ie: IEBC, IFC, IBC and so on
Plans shall indicate the type of building construction
Plans shall indicate if the building has fire sprinklers
03/19/2021 LOREN MAKUS ENGINEERING REVIEW Reqs Change THE DEVELOPMENT PACKAGE MUST BE APPROVED FIRST.
PLEASE PROVIDE PROJECT VALUATION FOR FLOODPLAIN USE PERMIT.