Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T20CM03547
Parcel: 113061840

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM03547
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/11/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM03547
2229 E Fort Lowell Rd
New SFR
Residential (1st Review)

TRANSMITTAL DATE: June 11, 2020

The SFR plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

1. Zoning has reviewed the model plan T20-M0010 to attempt to verify required perimeter yard setbacks. Sheet A-5 Elevations is missing needed dimensions. Also, for perimeter yard setbacks the wall height is measured from design grade not finished floor. Until fully dimensioned elevations are provided perimeter yard setbacks cannot be verified. Based on available information it does not appear that the following perimeter yard setbacks are met:
a. Based the 6'-0" perimeter yard setback shown for the east property line the maximum will height allowed would be 9'-0". It appears that the garage east wall height exceeds 13'.
b. The garage will need to meet one of the following to the back of sidewalk,
i. UDC Article 6.4.5.C.b.(1) A minimum setback of 19 feet from the back of sidewalk to allow sufficient space for a motor vehicle to be parked in front of the carport or garage is required as follows: (a) Eighteen feet (the length of a standard parking space) must be provided in front of the carport or garage and measured so that the full 18-foot parking space is available for parking on-site; and, (b) The 18-foot parking space shall be no closer than one foot from back of sidewalk of the street from which access is gained. (c) Modifications to the structural setback and parking space length requirements of this section for carports only in single-family and duplex development may be granted in accordance with Section 3.11.1, Design Development Option.
ii. UDC Article 6.4.5.C.b.(2) A minimum setback of one foot from the back of sidewalk of the street from which access is gained, is required if all of the following apply: (a) The street from which access is provided has a projected ADT of 140 vehicle trips or less; (b) The setback is measured so that the parking structure and the parking space within that structure are located completely on-site and do not encroach into the one-foot setback; and, (c) The distance between the street pavement edge and the parking structure is eight feet or less. The purpose of this requirement is to discourage motor vehicle tandem parking that would block the pedestrian area or overhang onto the roadway.
2. The lot coverage calculation needs to include the vehicle use areas, i.e. vehicle parking spaces, driveway and private street

3. This permit can not be approved until the lot is released and all required Assurance items have been completed. Contact John VanWinkle at John.VanWinkle@tucsonaz.gov or (520) 837-5007.

Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
06/16/2020 JVWINKL1 LANDFILL REVIEW Passed
06/16/2020 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change T20CM03547

1) Approval of DP20-0120 is required prior to approval of the building plans.

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
06/18/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed