Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T20CM03534
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/10/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Provide the total developed length from meter to the most remote appliance on the system, and verify the size of the supply pipe for the connected demand, G2413.3 & Table G2413.4(1). REPLACE THE 3/4" PIPE BETWEEN THE METER AND NEW JUNCTION WITH 1" FOR SUPPLYING THE TOTAL DEMAND OF 195,000 BTU. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/18/2020 | VFLORES1 | OUT TO CUSTOMER | Completed |