Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM03522
Parcel: 11206431B

Address:
2425 N TUCSON BL

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T20CM03522
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/11/2020 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
06/11/2020 JPEELDA1 FIRE REVIEW Approved
06/11/2020 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet A3; Floor Plan: A Section 1/A3 is cut through the new 36" pony wall. Please revise that section cut.
2. Sheet A3; Floor Plan: The interior elevation indicator at the new restroom should reference Sheet A4.
3. Sheet A5; Detail 3: The slip track connection at the top of the wall references a Detail 3/A8.1. Please revise that detail reference.
4. Sheet A5; Details 1, 3, and 4: Please indicate at the new metal stud walls to reference the Stud and Track Schedule on this sheet for stud sizes and spacings.
5. General: Please provide written responses to all review comments.
06/12/2020 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Provide the manufacturer's equipment data and installation instructions for the new equipment. Show that the equipment is being installed in accordance with the conditions of its listing and the manufacturer's installation requirements. Note that none of the depictions of the roaster show the required cooling tray exhaust fan or the required chaff collector. Reference: Sections 301 and 304.1, IMC 2018.
2. Clarify the material for the exhaust vent; single or double wall, type of connections (frequent disassembly is required for cleaning), and specific type of thimble to penetrate the roof assembly. Reference: Sections 501.14 and 503.7.5, IFGC 2018.
3. Provide maintenance access space for the equipment in accordance with the manufacturer's installation instructions. Reference: Sections 304.1 and 306.1, IMC 2018.
4. If the previous occupancy was not mercantile, provide calculations to verify that adequate ventilation will be provided for the occupied spaces. Reference: Section 403.3.1.1, IMC 2018.
5. Provide a roof plan to show the termination of the roaster exhaust system, how it relates to the existing rooftop equipment and compliance with Section 501.3.1 (1), IMC 2018 (the chaff from the roasting process is highly flammable).
6. Clarify the venting configuration for the roaster. Verify that termination of the exhaust vent with a Breidert cap meets with the manufacturer's installation instructions.
7. Show how adequate make-up air is to be provided to the room so that the room pressure remains essentially neutral. Reference: Section 501.4, IMC 2018.
06/12/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
06/12/2020 ROBERT SHERRY WATER REVIEW Completed
06/16/2020 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
06/18/2020 ALEXANDRA HINES ZONING REVIEW Approved
06/23/2020 ARUIZ1 ENGINEERING REVIEW Needs Review Engineering look at Wilson Wash sweeping through building footprint.