Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T20CM03499
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/17/2020 | ELISA HAMBLIN | ZONING | REVIEW | Reqs Change | Historic and design professional need to review to verify conistency with special approvals prior to approval from zoning. |
06/17/2020 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
06/17/2020 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Completed | |
06/17/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Passed | |
06/17/2020 | MGAYOSS1 | DESIGN PROFESSIONAL | REVIEW | Approved | DATE: June 15, 2020 TO: Maria Gayosso, Urban Planner/Principal Planner/Project Manager, City of Tucson FROM: Rick Gonzalez, Architect (#26992) COT On-Call Design Professional RE: CD Review, 375 South Stone Renovated Historic Garage, T20CM03499 I have reviewed the Historic Garage Renovation Construction Documents, submitted May 2020 for the purpose of determining its conformance with design requirements based upon Unified development Code (UDC) Section 5.12 IID (General Incentive Infill District); of the required plans and documents submitted to PDSD. Submittal Requirements Status 1. Streetscape Design: Within Parking Area pedestrian orientation: N/A Architectural elements/details at the 1st two levels – ground floor windows – 50% of frontage, single N/A existing facade plane 50' max with no architectural detail. ID historic structure front doors – graphics, lighting, or similar. Commercial or retail at 1st floor. Sidewalks – maintain with safe widths to adjoining properties with outdoor seating, dining, landscape, if existing maintain bus pull-outs, and safe drive-throughs. 2. Shade: Covered Garage 50% of sidewalk areas on Summer Solstice, use trees, N/A arcades, canopies, shade structures historically compatible with context except where not feasible. 3. Development Transition Standards: No heavy construction mitigate noise, odor, vibration relative to residential uses requirements - nearby. Maximum height 25-30' and 30' from property minimal sensory impact lines. Reduce bulk relative to residential, breaking mass, Bulk standards are not projected windows at 2nd level to reduce views into applicable to this residential areas. Balconies to orient away or screen from project residential areas. Buffer and screen from residential landscaping, walls, decorative features and other 'best complies practices. Orient service ares away from residential with mitigation methods described above, same with parking areas. Best Practice Alternatives may be offered for compliance. Provide site utility layouts... Utility layouts provided 4. Greater Infill Incentive Subdistrict Project augments an Modifications of underlying... dimensions, parking, existing approved loading, landscaping, NPP... exceptions (25%) parking plan 4.1. height – up to 60'; perimeter yard consistent with M N/A S and R plan, sight visibility, traffic safety... existing structure 4.2 Parking: up to 25% reduction except accessible parking; bike N/A reduced or eliminated based on acceptable requirements. Location: on-site, off site (within a ¼ mile with shared parking agreement. With DOT approval non-residential may have 5 spaces on-street. 4.3. Off-street loading: waived/reduced w/PDSD or DOT N/A approval. 4.4. Solid waste collection may be modified w/ESD N/A approval. 4.5. Landscaping/Screening: N/A NPP may not be modified; Exceptions may be granted if shade is provided for pedestrians/customers on circulation paths, outdoor patios or PDSD Director waiver. Existing landscape, right-of-way trees, green walls/roofs, shade structures are considered in compliance. 4.6. Alternative Pedestrian access: code compliant Complies connectivity: public entries to sidewalks. General Comments: Based on review of the 375 South Stone Renovated Historic Garage Plan Set 2020 05 29, I recommend approval as submitted. Sincerely, Rick Gonzalez, Architect RGA |
06/17/2020 | ROBERT SHERRY | WATER | REVIEW | Passed | |
06/17/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
06/17/2020 | JPEELDA1 | FIRE | REVIEW | Approved | |
07/10/2020 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
07/10/2020 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet G2; Code Review (Fire Barriers): A fire resistance rated wall or partition must be identified with a U.L. Listing Number or an Item Number from the IBC Table 721.1(2). Please indicate on this sheet, and provide wall detail as required. 2. Sheet G2; Floor Plan: A plan key indicates a one hour horizontal assembly at this structure. Please provide a U.L. Listing Number or an Item Number from the IBC Table 721.1(2). Please indicate on this plan, and provide floor detail as required. 3. General: Please provide written responses to all review comments. |
11/06/2020 | ARUIZ1 | HISTORIC | REVIEW | Needs Review |