Permit Number: T20CM03312
Parcel: 12402023B

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T20CM03312
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/01/2020 MALLORY RESS ZONING REVIEW Approved
06/01/2020 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
06/01/2020 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
06/01/2020 MRESS1 ENGINEERING REVIEW Passed
06/01/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change New or replacement faucet for the lavatory shall be a metering faucet. The metering faucet shall dispense a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds for accessibility. Reference: Section 412.11, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09
06/01/2020 ROBERT SHERRY WATER REVIEW Completed
06/01/2020 MARTIN BROWN FIRE REVIEW Approved
06/03/2020 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved