Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T20CM03300
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/20/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 08/20/2020 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 08/20/2020 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 08/27/2020 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 09/01/2020 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | I have included the comments from the previous review. Of the 19 comments, number 17 was the only one that was provided (architect's date on seal). 1. Sheet T1.1; Occupancy (Plumbing); Occupancy (Exiting): The Plumbing Occupancy indicates 22 persons in the 1620 SF, while the Exiting Occupancy indicates 39 persons in the 1620 SF. Please clarify. 2. Sheet T1.1; Exiting Plan: The north exit indicates 3 occupants and the south exit indicates 34 occupants for a total of 37 occupants. The Exiting Occupancy is indicated as 39. Please coordinate. 3. Sheet T1.1; Building Codes: Please add the 2009 ICC/ANSI A117.1 Accessibility Code. 4. Sheet T1.1; Tactile Exit Signage: The first note references 5/A9.2 for signage design and mounting requirements. Please revise that reference. 5. Sheet T1.1; Tactile Exit Signage: The second note references 9/A9.2 for accessible signage mounting/clearance requirements. Please revise that reference. 6. Sheet T1.1; Tactile Exit Signage: The third note references 10/A9.2 for tactile egress signage mounting requirements. Please revise that reference. 7. Sheet A1.0; Site Keynotes: Note SP-12 was not located on the plan. Please verify. 8. Sheet A2.1; Wall Legend: The first note references 4/A8.4 for typical wall types. Please revise that reference. 9. Sheet A2.1; Symbols: The first symbol references Sheet A7.4 for window type information. Please revise that reference. 10. Sheet A2.1; Symbols: The second symbol references Sheet A7.3 for door information. Please revise that reference. 11. Sheet A2.1; Symbols: The fourth symbol references Sheets A14.1 and A14.2 for turning radius information. Please revise that reference. 12. Sheet A2.1; Floor Plan Keynotes: Note FP-07 references 1/A9.2 for disabled access signage. Please revise that reference. 13. Sheet A2.1; Floor Plan Keynotes: Please complete Note FP-08. 14. Sheet A2.1; Floor Plan Keynotes: Note FP-11 references 5/A9.2 for tactile exit signs. Please revise that reference. 15. Sheet A6.1; Restroom Elevations 105A and 106C: Please indicate the vertical grab bar per the ICC/ANSI Figure 604.5.1. 16. Sheet A9.1; Detail 3: Please indicate the vertical grab bar per the ICC/ANSI Figure 604.5.1, including dimensions. 17. General: The professional seal of the registered architect must include the date the seal was signed. Please provide (all applicable sheets). 18. General: The professional seal of the registered civil engineer indicates the expiration date rather than the date the seal was signed. Please provide (all applicable sheets). 19. General: Please provide written responses to all review comments. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/07/2020 | PC_TGUTHEI1 | REJECT SHELF | Passed |
| 09/07/2020 | PC_TGUTHEI1 | APPROVAL SHELF | Passed |
| 09/07/2020 | PC_TGUTHEI1 | OUT TO CUSTOMER | Completed |