Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM03138
Parcel: 11807237C

Review Status: Completed

Review Details: COMMERCIAL - NEW

Permit Number - T20CM03138
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/27/2020 MARTIN BROWN FIRE REVIEW Approved
05/29/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide primary and secondary roof scuppers for the building additions (a hole in a collector box is not a secondary scupper). Determine the minimum dimensions of the two scuppers per Section 1106.5, IPC 2018. Reference: Section 1108, IPC 2018.
2. If a secondary roof scupper is not associated with the existing scupper, provide a secondary scupper or structural calculations to show that the roof is capable of supporting the maximum depth of ponded water on the roof if the existing scupper is blocked. Reference: Section 1611.1, IBC 2018 and Section 1101.7, IPC 2018.
05/29/2020 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Demonstrate energy code compliance for the addition to the building envelope using calculations based on the current code. Reference: Section C502.1, International Energy Conservation Code 2018.
2. Provide heating and cooling load calculations to justify the heating/cooling capacities of the specified HVAC units. Reference: Section C403.1.1 and C502.2.3, IECC 2018.
3. Provide locking access port caps for the condensing units per Section 1101.10, IMC 2018 or locate the condensing unit in a controlled space.
05/29/2020 ROBERT SHERRY WATER REVIEW Completed
06/04/2020 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
06/08/2020 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please provide complete compliance with the 2012 Tucson/Pima County Outdoor Lighting Code for the exterior lighting.
06/10/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: Leasing Office Addition
T20CM03138 - Related DP20-0101
Building Plan (1st Review)

TRANSMITTAL DATE: June 10, 2020

1. Zoning has reviewed the building plans for compliance with the submitted development package DP20-0101. While the building plans are consistent with the approved DP as it relates to the zoning review purview of the building footprint, building height, square footage, site conditions etc., zoning cannot approve the building plans until the DP has been approved and all PDSD Commercial Plans reviewers have approved the building plans.

2. The development package sheets provided within the building set must either be 1) the approved and stamped development package sheets, 2) stamped for reference only, or 3)removed from the building plan set.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
06/15/2020 LOREN MAKUS ENGINEERING REVIEW Reqs Change DP must be approved first.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/17/2020 JGARCIA1 APPROVAL SHELF Passed
07/17/2020 JGARCIA1 OUT TO CUSTOMER Completed
07/17/2020 JGARCIA1 REJECT SHELF Completed