Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T20CM03123
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/21/2020 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 05/22/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide a metering faucet for the lavatory in room 114, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds. Reference: Section 419.6, IPC 2018, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 2. At a minimum, coffee machines and non-carbonated beverage dispensers require the use of a backflow preventer listed to either ASSE 1022, ASSE 1024, or an air gap. Reference: Section 608.17.1.2, IPC 2018. |
| 05/22/2020 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 05/22/2020 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 06/02/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 06/08/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: Vantage West Credit Union - 801 E Speedway T20CM03123 Building Facade Remodel Plan (1st Review) TRANSMITTAL DATE: June 8, 2020 1. Zoning has reviewed the building plans for compliance with development package DP20-0071. Until DP20-0071 has been approved Zoning cannot approve the building plans. 2. Zoning cannot approve the building plans until PDSD Commercial Plans reviewers have approved the building plans. 3. The development package sheets provided in the building set either need to be the approved development package sheets, marked as for reference only, or removed from the plan set. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 06/16/2020 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. 1. Provide complete compliance with the 2012 Tucson/Pima County Outdoor Lighting Code for the exterior lighting. Include the 'E' luminaires in the luminaire schedule and exterior lumen calcs. Ref; 2018 IBC sec, 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements, 2012 Tucson/Pima County Outdoor Lighting Code |
| 06/23/2020 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Needs Review | |
| 06/23/2020 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/24/2020 | VLEON1 | APPROVAL SHELF | Completed |
| 08/24/2020 | VLEON1 | OUT TO CUSTOMER | Completed |
| 08/24/2020 | VLEON1 | REJECT SHELF | Completed |