Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Permit Number - T20CM02964
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/19/2020 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 05/19/2020 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 05/26/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T20CM02964 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. STRUCTURAL PLANS: 1. Show braced wall panel compliance for framed walls with a garage door opening, Table R602.10.5. For prescriptive braced wall structures show a portal frame with hold-downs PFH method, Figure R602.10.6.2, or a portal frame at garage door PFG method, Figure R602.10.6.3, or a continuously sheathed portal frame CS-PF method, Figure R602.10.6.4. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 06/12/2020 | STEVE SHIELDS | ZONING | REVIEW | Approved | ZONING REVIEW TRANSMITTAL FROM: Steve Shields Site Section Manager PROJECT: T20CM02964 1622 E Hampton St NR-1, Jefferson Park TRANSMITTAL: May 19, 2020 COMMENTS: the following comments are relative to an application for NPZ Review (UDC 5.10.3). This site is located in the NR-1 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. Prior to zoning approval an NPZ review and approval is required. Owner is proposing to construct n 20' x 22' x 11' 5"h detached garage. Structure meets setbacks. Contact Maria Gayosso, Maria.Gayosso@tucsonaz.gov, or Nick Ross, Nicholas.Ross@tucsonaz.gov for submittal requirements. |
| 06/12/2020 | STEVE SHIELDS | ZONING | REVIEW | Approved | T20CM02964 Detached Garage - 1622 E Hampton St - No NPZ Review is Needed ? Label: 90 Day Delete (3 months) Expires: Wed 9/9/2020 14:55 Maria Gayosso Thu 6/11/2020 14:55 View with a light background Like Reply Reply all Forward Hello Steve, The attached elevation and site plan for the proposed detached garage were reviewed by the PDSD Director, who determined the proposed detached garage's visibility from the street is so minimal as to be immaterial (UDC 5.10.3.A.1). Also, it was determined the garage could not be moved further to the west, due to the existing gate, masonry wall and landscaping on site, as described by the applicant. Please let me know if you need anything else you need from me to move the project forward. Thanks, Maria |