Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM02779
Parcel: 13312710A

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T20CM02779
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/07/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed THE DRAWING SHOWS A TOTAL DEVELOPED LENGTH OF 144 FEET WITH A TOTAL 210,000 BTU. tHEREFORE THE MAIN LINE FROM THE METER TO THE WATER HEATER BRANCH TEE SHOULD BE 1-1/4". UPDATE THE DRAWING.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/15/2020 SMONTES1 APPROVAL SHELF Completed
05/15/2020 SMONTES1 OUT TO CUSTOMER Completed
05/15/2020 SMONTES1 REJECT SHELF Completed