Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T20CM02707
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/03/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
06/03/2020 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
06/03/2020 | ROBERT SHERRY | WATER | REVIEW | Completed | |
06/18/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
06/29/2020 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
07/01/2020 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
07/08/2020 | JPEELDA1 | FIRE | REVIEW | Approved | IFC 2018 907.2.7 Group M. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group M occupancies where one of the following conditions exists: The combined Group M occupant load of all floors is 500 or more persons The Group M occupant load is more than 100 persons above or below the lowest level of exit discharge Please provide note stating that fire alarms are required |
07/09/2020 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet A101; Floor Plan: Near Grid Lines Z.2 and 7, a section cut references 1/AXXX. Please revise that reference. 2. Sheet A201; Reflected Ceiling Plan: Please indicate the exit lighting on this plan, or reference the Electrical Lighting Plan. 3. Sheet A402; Section 3: This section is cut on the plan at a location where the masonry column centerline is at Grid Line Z.2 rather than Z.1 as noted. Please verify. 4. Sheet A402 (Section 2); Sheet A501 (Section 1): Section 2/A402 indicates a steel frame. Please add that frame to the enlarged Wall Section 1/A501. 5. Sheet A601; Wall Types 1 and 2: Please indicate on these Wall Type Sections the top of the masonry wall, or reference the Wall Sections on Sheet A501. 6. Sheet S1.1; General Structural Notes (Foundations): A note indicates the foundation design is based on a soil report. Please provide that soil report for review. 7. Sheet S2.1; Boxed Note: This note indicates foundations are preliminary, not for construction. However, the Metal Building Calculations and Deferred Submittal Drawings are completed. The engineer of record should follow the IBC Section 107.3.4.1 and review those drawings and calculations, indicating that those documents have been reviewed and found to be in general conformance with the construction documents. 8. General: Please provide the structural calculations for the foundation design. 9. General: Please provide a Special Inspection Certificate with Parts A and B completed. 10. General: Please provide written responses to all review comments. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
07/13/2020 | JGARCIA1 | APPROVAL SHELF | Passed |
07/13/2020 | JGARCIA1 | OUT TO CUSTOMER | Completed |
07/13/2020 | JGARCIA1 | REJECT SHELF | Completed |