Permit Number: T20CM02705
Parcel: 122172470

Address:
3409 E ELIDA ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM02705
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/04/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET FOR THE ALTERATION OF AN ACCESSORY STORAGE STRUCTURE INTO DWELLING SPACE FOR RESPONSE TO VIOLATION T20DV00861.

Use the Residential Plan Requirements & Checklist at https://www.tucsonaz.gov/pdsd/residential-permits

Sample plans are available on request. PDSD-Residential@tucsonaz.gov

SITE PLAN:

Provide a site plan showing all buildings, R106.1.1. Show setbacks to property lines and location of utility lines to the building.

FLOOR PLAN:

Provide a floor plan showing each room with labeled function. Scale ¼” = 1’. Show window size.

SECTIONS - DETAILS:

Provide structural details showing code compliant materials and fasteners. Walls and ceiling require addition of insulation.

PLUMBING PLANS:

Provide piping details showing code compliant materials and sizes.

MECHANICAL PLANS:

Provide equipment details showing code compliant components and sizes.

ELECTRICAL PLANS:

Provide wiring details showing code compliant devices and sizes. Show circuit size with receptacles at all walls and lighting control at each doorway. Include a panel schedule.

INTERNATIONAL ENERGY CONSERVATION CODE:

Provide insulation details showing code compliant materials and sizes, N1101. Show insulation and U-value ratings.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
08/18/2020 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: T20CM02705
Mechanical Upgrade
3409 E Elida Street

TRANSMITTAL DATE: August 18, 2020

DUE DATE: August 18, 2020

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The following comments were not addressed.

1. Based on the most current aerial photo there is appears to be some type of structure located in the northeast corner of the site that does not appear to be permitted. Show this structure on site. This structure does not appear to meet perimeter yard setbacks to the north and east property line a neighbor setback waiver is required. The following text needs to be provide on the plot plan for both the neighbor to north and east and they both must sign and date.
"My Name is __________________and I am the owner of the property located at . I have reviewed the site plan and I have no objection to structure being located or constructed _____ from the property line as depicted on the site plan."

2. Based on the most current aerial photo there is appears to be some type of structure that has been attached to the northeast corner of the building. Provide permit information for this addition.

3. Code Enforcement has issued a notice of violation, T20DV00861, that must be cleared prior to approval of this permit.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised drawings